Hayward Blue Essense-20 | Trouble Free Pool It wont stop leaking. My EC40 bump handle doesnt feel right. I currently have Hayward RS750CA and it starts leaking underneath. At the end of last season we noticed a leak. The help at the pool store had no idea what could be wrong. Do I need to use lube on the gasket, how much sand should be in the filter? BLUE WORKS PCB Main Circuit Board Compatible with Hayward Goldline GLX-PCB-Main System Board Visit the BLUE WORKS Store 193 ratings $16999 FREE Returns Available at a lower price from other sellers that may not offer free Prime shipping. Its a Hayward pump. If you have a visible motor shaft, just behind the impeller, common on older pumps or booster pumps, you can just grab it with straight pliers and turn it back and forth. Hi, motors run about 140 F when running, so they are always hot to the touch. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. It is plugged into a gfi outlet. The pump itself works great. Shut down the power to the pump from the breaker for 15 minutes turn back on and try to run the pump. We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. That is the black cylinder in the rear of the motor, located at 9 oclock. But most plastic impellers are closed nowadays, with non-visible vanes. When I turn on the pump, it sucks water through but only 2/3 of basket is filled as if a suction leak. Any insight? Hi, Heyward (cool name! Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. and check each motor lead to ground. Motors have a thermal overload switch which will shut off the motor if it gets too hot to operate, and in such cases, it will turn itself back on again after it cools, usually in 15-20 mins. Chapter 1: The Evil Emperor's Son. After reinstalling, give it the full charge of DE powder, plus a little extra. If the gears are not moving, either the motor for the clock is dead, or insects or lizard is stuck in the gears, or the breaker is tripped or off, or the breaker is bad. If it is not a clog, it could be a collapsed skimmer line or drain line, if flex pipe was used underground on these lines. Might wait to see if Hayward can give you an answer and probably want to contact the vendor who sold you the pump, which Hayward may require anyway? I sent a sample to the store and my salt level is 3400 and the reading shown is 4300. Yes this pool was install without GFCI protection, (of course we will installing an equipment ground and GFCI Breakers.) Professional Profile, View All Yes, you can briefly test motors, for a few seconds without water, no problem. Some inground pools used Flex PVC pipe to connect skimmers, and over 20-30 years, Flex pipe can develop internal nodules like polyps, that restrict flow. Is Kimchi Good For Acid Reflux, Genesee Community College Basketball, Articles H
">

hayward blue essence troubleshooting

hayward blue essence troubleshooting

If the bolts do not tighten fully, it could be that the housing threaded receivers are loose and spinning as you try to tighten the bolts. Look for any small drips or oozing around the filter, or you may be able to hear a small hiss, when the pump shuts off. It could also be something wrong with the motor, something internal with the windings, or shaft, or bearings, causing excess heat. filter. I will try that tonight. registration, authorized Hayward Super Pump, 1 Hp running on 240V, 3 yrs old The switch or voltage selector, I believe it should be only over one tab, but check the owners manual, or the wiring diagram on the motor. Weve tried everything. Can you help? In the last couple weeks it started getting louder at various times throughout the day. I do not have a owners manual and need help on draining the water from the feature and pump. We hope these charts help solve your Hayward pool heater problems. 2. pump lid The capacitor is at 9 oclock and the thermal regulator at 12 oclock. Anyway I decided to run it and it appears that the pump runs full power with the returns pushing out with lots of force for about 5 minutes and then it weakens. If it makes no noise at all, check that the GFCI test button is not tripped, and flip the circuit breaker off and back on. After 30 seconds it overheats and shuts down. Hi, I have a Hayword pump and when I turn the pump on I have water coming out the bottom of the pump in the back, and trips the GFI OUTLET, could this be a bad seal? The pump may be reversible, able to accept either 115V or 230V, so the incoming voltage must match the set-up, +/- 10%. There could also be a short in the wiring to the pump, or from the breaker to the switch. I have a Hayward Super Pump Model:C48L2N134B1 that I replaced 3 or 4 seasons ago and until now I have had no trouble out of it. The new pump was very quiet yesterday when I installed it, but this morning, I notice there is a slight medium pitch hum in the system. What are some items I should check assy A for on the bench so I can possibly repair it? i have an in ground pool. But heaters? Troubleshooting pool heaters is a methodical process, or a process of elimination. Nothin seems to be leaking anywhere. I have removed and tested the capacitor it appears OK I then removed the thermostat to try to access the shaft and turn it with a 7/17 wrench, but the protrusions on the casting and other spring mounted stuff appear to make it impossible to get a grip on the shaft. You can patch the fitting usually with pool putty or silicone, but the best repair is to replace the fitting. Spillover is just the spa filling up, and overflowing into the pool, a waterfall feature is something different, with dedicated plumbing and a booster pump usually. dont know if the pump went bad already. Checked pump later, not running with message Drive error, heatsync overheated. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. It had been running ok this summer. For the filter, its a common problem, but its usually solved with soaking the fingers in a DE filter cleaner solution, or acid. So, grab the opening portion with pliers, while the wrench is holding the shaft still, and turn counter clockwise, it should come off, if it breaks, a new impeller is needed, but thats rare, they usually will budge. Check that the shaft spins properly, and recheck all wiring. Backwash several times to remove as much DE powder as possible, and then add 4 cups of DE powder for every 10 sq ft of filter surface area (see filter label if unsure). If not, then it will usually be a bad capacitor, or start capacitor, located at 9 oclock, in the rear, a black cylinder. After about 15minutes the pump stopped and the motor was super hot. Or does the breaker need a reset? The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Hi Amy, the timer is usually wired between the pump and the breaker. The shaft turned with zero resistance. Home / Pool Equipment / Pool Pumps / Hayward Pool Pump Troubleshooting. http://www.inyopools.com/blogSHOP at our online store! Specialties: Cycling, Kickboxing, This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. Is this normal? Thank you I have taken the thing apart several times and cleaned those fingers but that wasnt the problem this timeI took a chance and tried the vacuum to see if any debris actually made it to the filter basket and nothing went throughso got a plunger and forced the water through with that and then the pump finally primed!! Joe, must be a bad motor yeah, to pull 58 amps, never heard of such a thing! After the pump and filter are fully drained, screw the plugs back in slightly to keep bugs out, but leave them loose so they will still drain, as needed. A sticky skimmer weir door can cause water blockage to the skimmer, and give priming problems too. 1.5 horse power. From the Hayward Ecostar Owners Manual: the Heat Sink Overheated error indicates that the heatsink on the bottom of the drive has overheated. Thanks. It just started leaking at the top plumbing connection. Secondly, check that there are no air leaks in FRONT of the pump, typically around the pump lid, or on the pipe coming into the pump. Please help. Tonight, I tried to manually start the filter and all I hear is a click in the mother board. I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. Something got fried, sorry! Hi Tracy, the C48 number is not the pump model, but the motor number. First time pool owner (obviously dont know what we are doing). Please help! Flipping the switch makes nothing happen. has it broken? Yesterday the breaker tripped. They have to stick out about 1/8 wider than the plunger disk. What you want is the owners manual for the heater. Ive checked all my hoses for clogs and skimmer and pump baskets are clean. Motor rate state 4 as a max amps, I dont notice a strange noise and water is flowing normal when running, I dont have a check valve in front of pump so it takes 1 minute to get prime, could you help me with a potential root cause.? Manually spinning the shaft can break the rust bonds. You are also using the diffuser? Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. I would like to repair it if possible. Would this make the breaker flip? This ONLY happens when I connect my vac hose. Also, if there is a GFCI outlet connected, perhaps it is tripped? I cant imagine paying someone to take 2 bolts off. If the motor label says 115V/230V it is reversible, but if it says just 230V, Hi Chad, If thats not it check the rear of the motor for anything loose (capacitor, centrifugal switch (in the center, on the shaft) or the stationary switch, at 6 oclock, triangular shape. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. Hayward Blue Essense-20 | Trouble Free Pool It wont stop leaking. My EC40 bump handle doesnt feel right. I currently have Hayward RS750CA and it starts leaking underneath. At the end of last season we noticed a leak. The help at the pool store had no idea what could be wrong. Do I need to use lube on the gasket, how much sand should be in the filter? BLUE WORKS PCB Main Circuit Board Compatible with Hayward Goldline GLX-PCB-Main System Board Visit the BLUE WORKS Store 193 ratings $16999 FREE Returns Available at a lower price from other sellers that may not offer free Prime shipping. Its a Hayward pump. If you have a visible motor shaft, just behind the impeller, common on older pumps or booster pumps, you can just grab it with straight pliers and turn it back and forth. Hi, motors run about 140 F when running, so they are always hot to the touch. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. It is plugged into a gfi outlet. The pump itself works great. Shut down the power to the pump from the breaker for 15 minutes turn back on and try to run the pump. We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. That is the black cylinder in the rear of the motor, located at 9 oclock. But most plastic impellers are closed nowadays, with non-visible vanes. When I turn on the pump, it sucks water through but only 2/3 of basket is filled as if a suction leak. Any insight? Hi, Heyward (cool name! Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. and check each motor lead to ground. Motors have a thermal overload switch which will shut off the motor if it gets too hot to operate, and in such cases, it will turn itself back on again after it cools, usually in 15-20 mins. Chapter 1: The Evil Emperor's Son. After reinstalling, give it the full charge of DE powder, plus a little extra. If the gears are not moving, either the motor for the clock is dead, or insects or lizard is stuck in the gears, or the breaker is tripped or off, or the breaker is bad. If it is not a clog, it could be a collapsed skimmer line or drain line, if flex pipe was used underground on these lines. Might wait to see if Hayward can give you an answer and probably want to contact the vendor who sold you the pump, which Hayward may require anyway? I sent a sample to the store and my salt level is 3400 and the reading shown is 4300. Yes this pool was install without GFCI protection, (of course we will installing an equipment ground and GFCI Breakers.) Professional Profile, View All Yes, you can briefly test motors, for a few seconds without water, no problem. Some inground pools used Flex PVC pipe to connect skimmers, and over 20-30 years, Flex pipe can develop internal nodules like polyps, that restrict flow.

Is Kimchi Good For Acid Reflux, Genesee Community College Basketball, Articles H

div#stuning-header .dfd-stuning-header-bg-container {background-image: url(https://kadermedia.com/wp-content/uploads/2017/04/slider.jpg);background-size: initial;background-position: top center;background-attachment: initial;background-repeat: no-repeat;}#stuning-header div.page-title-inner {min-height: 650px;}
Contact Form
close slider